Fire Alarms

Conventional control panels with 2 zones or 4 zones expandable to 36
The SmartLine conventional fire-detection control panel series offers a 2 zone non-expandable model (SmartLine020-2), a 4 zone model expandable to 20 zones (SmartLine020-4) and a 4 zone model expandable to 36 zones (SmartLine036). The extreme compactness, trouble-free installation, uncomplicated programming procedures and simple end-user operation make this highly competitive control panel ideal for all small and medium applications, especially those applications where fast installation and programming are among the most important aspects of the system.
​
Conventional detectors
Iris series detectors maintain the ease-of-use of conventional detectors, yet are capable of providing a series of technical solutions that until today were provided by only the most sophisticated addressable analogue systems. As a result of advanced technologies based on new-generation microprocessors, these detectors implement a set of sophisticated algorithms capable of ensuring unequalled reliability and a high immunity to false alarms.


SmartLight
​
Single loop analogue-addressable fire detection control panel
The compactness, simple end-user operation, trouble-free installation and uncomplicated programming procedures make this highly competitive control panel ideal for small applications that require first rate performance. It is exactly this market segment that the SmartLight control panel finds its niche. It is perfect for those applications which require a limited number of detectors yet call for the reliability and performance that only analogue-addressable systems can provide. With this application typology in mind, SmartLight is a valid alternative to conventional systems.
​
​
SmartLoop
Networkable analogue addressable fire alarm control panel with 1 loop expandable to 8
The SmartLoop series of analogue addressable fire control panels marks a clear evolution from previous generations. This series has solutions to satisfy all market segments: from small domestic applications requiring 1 loop to large applications requiring 8 loops. At maximum configuration a SmartLoop system can support 30 control panels (arranged in a token-ring) and, if you consider that each control panel can manage up to 8 loops, and that each loop can accommodate as many as 240 devices, it is clearly apparent that the cutting-edge technology of the SmartLoop series has achieved excellence in application flexibility.


So what makes thefirebeam head unit so special?....
​
The firebeam protection system includes a motorized head unit containing an infra-red transmitter and receiver, a ground level controller and prism reflector. Making use of the prism reflector the returned infrared beam is analysed for smoke contamination and registers a fire condition at a pre determined level. At ground level the controller unit is used to make operational adjustments. The standard Protection system covers a range of 5 to 40 meters, 2 further range kits are available, a 40 to 80 meter kit that utilities 4 reflectors and finally a 80 to 100 meter kit that makes use of 9 reflectors.


ProPointPlus Optical ‘Smoke’ and ‘Smoke/CO’ detection
Aspirating detection is now a recognised solution for many different fire detection applications.
ProPointPlus provides up to four separate detectors within a common aspirator enclosure and therefore provides four individually identifiable areas of detection per aspirator.
Each of the four plug-in ‘Scatter Chamber Detectors’ (SCD)’s detector modules can be either ‘optical’ only or combined ‘optical/enhanced CO’ detectors, the CO sensor is only suitable for small room applications. Independent and integrated
alarm decision making through the use of complex algorithms extend the range of particle detection, confirm genuine alarms
and reduce unwanted alarms.